E-mail: service@1001718.com
橫河電機(jī)EJX115A壓力變送器115A
橫河電機(jī)EJX115A壓力變送器高性能差壓變送器ejx110a單晶硅諧振傳感器的特點(diǎn),適用于測(cè)量液體、氣體或蒸汽的流量,?以及液位、密度和壓力。ejx110a輸出4到20毫安直流信號(hào)測(cè)量壓差。其高度精確和穩(wěn)定的傳感器還可以測(cè)量靜態(tài)壓力可以對(duì)積分指示器顯示或遠(yuǎn)程監(jiān)控通過(guò)腦或HART通訊。其他關(guān)鍵功能包括快速響應(yīng),遠(yuǎn)程設(shè)置使用通信,診斷和可選的狀態(tài)輸出的壓力高/低報(bào)警。
橫河電機(jī)EJX115A壓力變送器115A的詳細(xì)資料
橫河電機(jī)EJX115A壓力變送器
The high performance differential pressure transmitter EJX110A features single crystal silicon resonant sensor and is suitable to measure liquid, gas, or steam ? ow as well as liquid level, density and pressure. EJX110A outputs a 4 to20mA DC signal corresponding to the measured differential pressure.
Its highly accurate and stable sensor can also measure the static pressure which can be shown on the integral indicator or remoy monitored via BRAIN or HART communications. Other key features include quick response, remote set-up using communications, diagnostics and optional status output for pressure high/low alarm. The multi-sensing technology provides the advanced diagnostic function to detect such abnormalities as an impulse line blockage or heat trace breakage. FOUNDATION Fieldbus and PROFIBUS PA protocol types are also available. All EJX series
models in their standard con? guration, with the exception of the Fieldbus and PROFIBUS types, are certi? ed by TÜV as complying with SIL 2 for safety requirement.
? STANDARD SPECIFICATIONS
Refer to GS 01C25T02-01EN for Fieldbus
communication type and GS 01C25T04-01EN for
PROFIBUS PA communication type for the items
marked with “◊.”
□ SPAN AND RANGE LIMITS
Measurement
Span/Range kPa inH2O
(/D1)
mbar 橫河電機(jī)EJX115A壓力變送器
(/D3)
mmH2O
(/D4)
F*
Span 0.1 to 5 0.4 to201 to 50 10 to 500
Range -5 to 5 -20 to20-50 to 50 -500 to
500
L*
Span 0.1 to 10 0.4 to 40 1 to 100 10 to 1000
Range -10 to 10 -40 to 40 -100 to
100
-1000 to
1000
M
Span 0.5 to 100 2 to 400 5 to 1000 50 to
10000
Range -100 to
100
-400 to
400
-1000 to
1000
-10000 to
10000
H
Span 2.5 to 500 10 to 2000 25 to 5000 0.025 to 5
kgf/cm2
Range -500 to
500
-2000 to
2000
-5000 to
5000
-5 to 5
kgf/cm2
V
Span 0.07 to 14
MPa
10 to 2000
psi
0.7 to 140
bar
0.7 to 140
kgf/cm2
Range -0.5 to 14
MPa
-71 to
2000
-5 to 140
bar
-5 to 140
kgf/cm2
*: F capsule is applicable for wetted parts material
code S.
L capsule is applicable for wetted parts material
code other than S.
PERFORMANCE SPECIFICATIONS
Zero-based calibrated span, linear output, wetted
parts material code S and silicone oil, unless
otherwise mentioned.
For Fieldbus and PROFIBUS PA communication
types, use calibrated range instead of span in the
following specifi cations.
Specifi cation Conformance
EJX series ensures specifi cation conformance to at
least ±3σ.
Reference Accuracy of Calibrated Span
(includes terminal-based linearity, hysteresis, and
repeatability)
Measurement span F
Reference
accuracy
X ≤ span ±0.04% of Span
X > span ±(0.015+0.01 URL/span)% of Span
X 2 kPa (8 inH2O)
URL
(upper range limit) 5 kPa (20 inH2O)
Measurement span M
Reference
accuracy
X ≤ span ±0.04% of Span
X > span ±(0.002+0.0019 URL/span)% of Span
X 5 kPa (20 inH2O)
URL
(upper range limit) 100 kPa (400 inH2O)
Measurement span H
Reference
accuracy
X ≤ span ±0.04% of Span
X > span ±(0.005+0.0049 URL/span)% of Span
X 70 kPa (280 inH2O)
URL
(upper range limit) 500 kPa (2000 inH2O)
Measurement span V
Reference
accuracy
X ≤ span ±0.04% of Span
X > span ±(0.005+0.00125 URL/span)% of Span
X 500 kPa (2000 inH2O)
URL
(upper range limit) 14 MPa (2000 psi)
Square Root Output Accuracy
The square root accuracy is a percent of flow span.
Output Accuracy
50% or Greater Same as reference accuracy
50% to Dropout point Reference accuracy × 50
Square root output (%)
Ambient Temperature Effects per 28°C (50°F)
Change
Capsule Effect
F
M
H, V
±(0.055% Span+0.18% URL)
±(0.04% Span+0.009% URL)
±(0.04% Span+0.0125% URL)
? Total Probable Error (M capsule)
±0.12% of Span @1:1 to 5:1 Rangedown
Total probable error, known as a measure of the total
performance of the transmitters under the condition of
fixed line presurre.
Total Probable Error=± E1
2+E2
2+E3
2
E1: Reference Accuracy of Calibrated Span
E2: Ambient Temperature Effects per 28°C change
E3: Static Span Effects per 6.9 MPa change
? Total Accuracy (M capsule)
±0.12% of Span @1:1 Rangedown
±0.25% of Span @ 5:1 Rangedown
Total accuracy is a comprehensive measure of
transmitter total performance, covering all major
factors in actual installation, that cause errors in
measurement.
As a standard measure, YOKOGAWA uses this to
evaluate transmitter performance.
Total Accuracy=± E1
2+E2
2+(E3+E4)
2+E5
2
E1: Reference Accuracy of Calibrated Span
E2: Ambient Temperature Effects per 28°C change
E3: Static Span Effects per 6.9 MPa change
E4: Static Zero Effects per 6.9 MPa change
E5: Overpressure Effects upto overpressure 25MPa
Not only a day-to-day changes in temperature can
affect the measurement and lead to unnoticed errors;
fluctuaion of line pressure, incorrect operation of
three/five valve manifold leading to over-pressure
events, and other phenomena can have the similar
result. Total Accuracy factors in such changes and
errors and provides much comprehensive and
practical determination of how a transmitter will
perform under actual plant operation.
Static Pressure Effects per 6.9 MPa (1000 psi)
Change
Span Effects
F, M, H and V capsules
±0.075% of span
Effect on Zero
Capsule Effect
F
M
H, V
±0.1% URL
±0.02% URL
±0.028% URL
Overpressure Effects
Overpressure condition: up to maximum working
pressure
M, H and V capsules
±0.03% of URL
Stability (All normal operating condition, including
overpressure effects)
M, H and V capsules
±0.1% of URL per 10 years
F capsule
±0.1% of URL per one year
Power Supply Effects(Output signal code D, E
and J)
±0.005% per Volt (from 21.6 to 32 V DC, 350Ω)
Vibration Effects
Amplifier housing code 1 and 3:
Less than 0.1% of URL when tested per the
requirements of IEC60770-1 field or pipeline
with high vibration level (10-60Hz, 0.21mm
displacement/60-2000Hz 3 g)
Amplifier housing code 2:
Less than ±0.1% of URL when tested per the
requirements of IEC60770-1 field with general
application or pipeline with low vibration level (10-60
Hz 0.15mm displacement /60-500Hz 2g)
Mounting Position Effects
Rotation in diaphragm plane has no effect. Tilting
up to 90 degree will cause zero shift up to 0.4 kPa
(1.6 inH2O) which can be corrected by the zero
adjustment.
Response Time (Differential pressure) “◊”
90 ms for Wetted Parts material code S except for
Measuring span code F. 150 ms for Wetted Parts
Material Code H, M, T, A, B, D and W or Measuring
span code F.
When amplifier damping is set to zero and including
dead time of 45 ms (nominal)
Static Pressure Signal Range and Accuracy
(For monitoring via communication or on
indicator. Includes terminal-based linearity,
hysteresis, and repeatability)
Range
Upper Range Value and Lower Range Value of the
statice pressure can be set in the range between 0
and Maximum Working Pressure(MWP). The upper
range value must be greater than the lower range
value. Minimum setting span is 0.5 MPa(73 psi).
Measuring either the pressure of high pressure side
or low pressure side is user-selectable.
該產(chǎn)品由深圳市銀飛電子科技有限公司提供,銷售商地址位于深圳市南山區(qū)前海路振業(yè)國(guó)際商務(wù)中心1206。請(qǐng)您仔細(xì)閱讀產(chǎn)品使用說(shuō)明書,正確使用。
如果想試用該產(chǎn)品,請(qǐng)以下單位:
銀飛電子主要銷售通信設(shè)備、儀器儀表、電力設(shè)備、熱工儀表、校準(zhǔn)設(shè)備及工具配件。
歡迎關(guān)注我們網(wǎng)站平臺(tái)
|
||||